Control board settings, Dip switches, Auto close – Mighty Mule FM502 Dual Swing - Blue Board User Manual

Page 28: Main dip switch settings (modes)

Advertising
background image

24

1 2 3

4

ON DIP

STATUS

LEARN RMT

LEARN

MAST LIMIT

LEARN

SLV LIMIT

S3

S4

S2

OFF

SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF

ON
ON
PUSH
SIMULT.
ON
ON

120 MIN

MAX

AUTO CLOSE TIME

STALL FORCE

1 2 3

4

ON DIP

STATUS

LEARN RMT

LEARN

MAST LIMIT

LEARN

SLV LIMIT

S3

S4

S2

OFF

SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF

ON
ON
PUSH
SIMULT.
ON
ON

120 MIN

MAX

AUTO CLOSE TIME

STALL FORCE

1 2 3

4

ON DIP

SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF

ON
ON
PUSH
SIMULT.
ON
ON

120 MIN

ON

OFF

1

ON

DIP

23

4

CONTROL BOARD SETTINGS

DIP Switches

NOTE:

Leave DIP Switch #3 in the OFF position until installation is complete, to prevent gate from

automatically closing during installation.

Auto Close Time Pot

1 2 3

4

ON

DIP

STATUS

LEARN RMT

LEARN

MAST LIMIT

LEARN

S3

S2

OFF

SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF

ON
ON
PUSH
SIMULT.
ON
ON

120 MIN

MAX

AUTO CLOSE TIME

STALL FORCE

Main DIP Switch Settings (MODES)

DIP Switch #1 - Soft Start/Stop

ON - Soft start enabled (factory preset).

OFF - Soft start disabled.

The Soft Start/Stop feature slowly starts the gate
as it begins to open and slows the gate as it comes
to the closed position. This saves wear and tear on
the gate and gate opener system.

DIP Switch #2 - Warning Buzzer

ON - Buzzer warning enabled (factory preset).

OFF - Buzzer warning disabled.

The Warning Buzzer alerts you when the gate
opener is beginning to either open or close the
gate. It sounds for the first 2 seconds in each
direction. It also sounds a warning when the gate
obstructs two times in one cycle. Switching this to
OFF only disables the open and close warning not
the obstruction warning.

DIP Switch #3 - Push/Pull-to-Open

ON - Push to open.

OFF - Pull to open (factory preset).

If your gate opens into the property the DIP
Switch is set to the OFF position (factory setting).
If your gate opens out from the property the DIP
Switch must be set to the ON position. NOTE:
if you have a Push-to-Open gate application you
will need a Push-to-Open bracket (see Push-to-
Open Instructions on page 30).

DIP Switch #4 - Delay/Simultaneous operation

ON - Slave opens simultaneously with master.

OFF - Slave opens after master.

NOTE: Not applicable for single gate operator.

Auto Close

The 'AUTO CLOSE TIME' pot controls

auto close feature.

Turning the pot all the way counter-clockwise
will turn auto close feature off. The minimum
auto close time is 3 seconds. The maximum
(turn the pot all the way clockwise) auto close
time is 120 seconds.