Step 3, Step 4, Step 5 – Mighty Mule FM502 Dual Swing - Blue Board User Manual

Page 38: Step 6, Step 7

Advertising
background image

34

Step 3

Note which gate has reached the desired closed position (typically it's the slave gate), program the closed limit setting by
pressing and holding the corresponding 'LEARN MAST LIMIT' or 'LEARN SLV LIMIT' button for 5 seconds.

Step 4

Press the transmitter button and allow the gates to return to the closed position. YOUR FIRST GATE’S OPEN POSITION
LIMIT IS NOW PROGRAMMED.

Step 5

Activate your openers again by pressing the
entry transmitter button. Your gates should now
be moving from the closed positions toward
their open positions. The first gate will stop at
the spot you just programmed and the second
gate will continue to open until you press the
transmitter button again. Press the transmitter
button when the second gate reaches the desired
open position. This step may be repeated until
desired open position is achieved. Once the
desired OPEN position has been achieved,
proceed to step 6.

Step 6

Repeat step 3 for the other gate that has not been
set in step 3.

Step 7

Press the transmitter button and allow the
gates to return to the closed position. BOTH
YOUR MASTER AND SLAVE GATE’S
OPEN POSITION LIMITS ARE NOW
PROGRAMMED.

TESTING YOUR OPEN LIMIT SETTING:

Press your entry transmitter and allow your gates to open. If OPEN positions are not correct or need to be changed, you will
need to CLEAR your OPEN LIMIT settings and follow steps one (1) to seven (7) again.

CLEARING THE PROGRAMMED OPEN LIMIT SETTING:

If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their closed
positions, then press and hold the 'LEARN MAST LIMIT' or 'LEARN SLV LIMIT' button for 5 seconds. This will clear the
memory for the open limit positions. Follow steps one (1) to seven (7) again.

1 2 3

4

ON

DIP

STATUS

LEARN RMT

LEARN

MAST LIMIT

LEARN

SLV LIMIT

S3

S4

S2

ART OFF

G OFF

PULL

EN DLY.

OFF
OFF

ON
ON
PUSH
SIMULT.
ON
ON

120 MIN

MAX

CLOSE TIME

STALL FORCE

Learn Master Limit

Button

Learn Slave Limit

Button

Advertising