Troubleshooting guide, Audible feedback – Mighty Mule FM502 Dual Swing - Blue Board User Manual

Page 39

Advertising
background image

35

Troubleshooting Guide

If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department.

Audible Feedback

Symptom

Diagnosis

Check:

1 short beep upon activation Blown Fuse

Low or Bad Battery
Loose Battery Connection

Fuse
Battery Under Load
Battery Harness Connections

1 short beep upon power up Circuit Board Powered Up &

Ready

Normal Operation

Continuous Uninterrupted
Alarm

Circuit Board Senses an
Obstruction

Path of Gate
Gate for Level and Plumb
Stall Force Adjustment
Disconnect Safety Devices
Rev Counter

1 beep with 10 seconds off Low Battery Condition

Fuses
Battery Harness Connections
Battery Under Load

1 beep then 2 beeps

Master Motor Terminals
Shorted

Connections to Master Inputs

Master Arm Power Cable

• Motor

Circuit Board

1 beep then 3 beeps

Slave Motor Terminals
Shorted

Connections to Master Inputs

Master Arm Power Cable

• Motor

Circuit Board

1 beep with 2 seconds off

Master Arm Limit Switch
Error

Connections to Master Inputs

Master Arm Power Cable

Master Input ORG & GRN, BRN & GRN voltage with
wires disconnected. 11VDC across each terminal.

2 beeps with 2 seconds off

Slave Arm Limit Switch Error

Connections to Slave Inputs

Slave Arm Power Cable

Slave Input ORG & GRN, BRN & GRN voltage with
wires disconnected. 11VDC each across each terminal.

3 beeps with 2 seconds off

Master Arm Rev Counter
Error

Connections to Master Inputs

Master Arm Power Cable

Rev Counter

4 beeps with 2 seconds off

Slave Arm Rev Counter Error

Connections to Master Inputs

Master Arm Power Cable

Rev Counter

Advertising