English, Compatibility, Location – DeWalt D55695 User Manual

Page 17

Advertising
background image

17

English

DIsConneCtInG Hoses

WARNING: Risk of unsafe operation. Firmly grasp hose in hand

when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Remove hose(s) from air outlet(s) (G).

Lubrication and oil

enGIne
1. The engine was filled

WItH oil at the manufacturer. Check engine

oil level before operating unit. If necessary, fill engine to the

appropriate level with recommended oil, see engine's instruction

manual supplied by engine manufacturer for correct procedure.

2. Add fuel to engine. See engine's instruction manual supplied by

engine manufacturer for correct procedure.

WARNING: Risk of explosion or fire. Gasoline vapor is highly

flammable. Refuel outdoors preferably, or only in well-ventilated

areas. Do not refuel or check gasoline level while the engine is

running. Do not store, spill or use gasoline near an open flame,

a source of sparks (such as welding), or near operating electrical

equipment.
AIr CoMPressor
The air compressor pump was filled

WItH oil at the manufacturer.

Check air compressor pump oil level before operating unit. See

Compressor Pump oil under Maintenance.

Compatibility

Air tools and accessories that are run off the compressor must be

compatible with petroleum based products. If you suspect that a

material is not compatible with petroleum products, an air line filter

for removal of moisture and oil vapor in compressed air is required.
note: Always use an air line filter to remove moisture and oil vapor

when spraying paint.

Location

WARNING: Risk of breathing. Exhaust from the gasoline engine

contains deadly carbon monoxide, which is odorless and toxic.

Operate engine only in well ventilated areas.
CAUTION: Risk of property damage. In order to avoid damaging

the air compressor, do not allow the unit to be tilted more than 10º

when operating.
Place air compressor at least 4 ft (1.2 m) away from obstacles that

may prevent proper ventilation. Keep unit away from areas that have

dirt, vapor and volatile fumes in the atmosphere which may clog and

gum up the intake filter and valves, causing inefficient operation.
HuMID AreAs
In frequently humid areas, moisture may form in the pump and

produce sludge in the oil, causing running parts to wear out

prematurely. Excessive moisture is especially likely to occur if

the unit is located in an unheated area that is subject to large

temperature changes. Two signs of excessive humidity are external

condensation on the pump when it cools down and a “milky”

appearance in compressor oil. You may be able to prevent moisture

from forming in the pump by increasing ventilation or operating for

longer intervals.
noIse ConsIDerAtIons
Consult local officials for information regarding acceptable noise

levels in your area. To reduce excessive noise, use vibration mounts

or silencers, relocate the unit or construct total enclosures or baffle

walls. Contact a D

e

WALT service center or call 1-800-4-D

e

WALT for

assistance.
trAnsPortInG

WARNING: Risk injury from lifting. Unit weighs more than 160 lbs.

(72.6 kg) Do not move or lift without assistance.

Advertising