CoDe

PossIble CAuse

PossIble solutIon

1

Unloader valve does not release pressure when air tank

reaches

blow-off pressure

Unloader valve must be replaced. Contact a D

e

WALT factory

service center or a D

e

WALT authorized service center.

2

Fittings are not tight

Tighten fittings where air can be heard escaping. Check fit-

tings with soapy water solution. DO NOT OVERTIGHTEN.

3

Defective unloader valve

Turn off engine, rotate manual lock unloader lever to the

closed perpendicular position. If air leaks out of air tank

through unloader valve, replace unloader valve.

4

Defective air tank

Air tank must be replaced. Do not repair the leak.

WARNING: Risk of bursting. Do not drill into, weld or oth-

erwise modify air tank or it will weaken. The air tank can

rupture or explode.

5

Leaking seals

Contact a D

e

WALT factory service center or a D

e

WALT

authorized service center.

6

Defective safety valve

Operate safety valve manually by pulling on ring. If valve still

leaks, it must be replaced.

7

Prolonged excessive use of air

Decrease amount of air usage.

8

Compressor is not large enough for accessory

Check the accessory air requirement. If it is higher than the

SCFM or pressure supplied by your air compressor, a larger

compressor is needed to operate accessory.

9

Hole in air hose

Check and replace air hose, if required.

10

Unloader valve restricted

Remove, clean or replace.

11

Unit operating in damp or humid conditions

Move unit to a dry well ventilated area.

12

Restricted air intake filter

Clean or replace air intake filter.