English, Checking safety valve (fig. 1), Checking air filter element (fig. 1) – DeWalt D55695 User Manual

Page 22: Draining air tank (fig. 1)

Advertising
background image

22

English

Procedure

Daily

Weekly Monthly

1 year or

200 Hours

Check for unusual noise/
vibration

X

Check for air leaks*

X

Clean compressor exterior

X

Engine

See engine instruction manual.

* To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
** The pump oil must be changed after the first 20 hours or operation.
Thereafter, when using

D

e

WALT

synthetic compressor oil, change oil

every 200 hours of operation or once a year, whichever comes first.
+ Perform more frequent in dusty or humid conditions.

Checking Safety valve (Fig. 1)

WARNING: Hot surfaces. Risk of burn. aftercooler, pump head,

and surrounding parts are very hot, do not touch (see the Hot

Surfaces identified in Fig. 2). allow compressor to cool prior to

servicing.

WARNING: Risk of bursting. If the safety valve does not work

properly, over-pressurization may occur, causing air tank rupture or

an explosion.
Before starting compressor, pull the ring on the safety valve to

make sure that the safety valve operates freely. If the valve is stuck

or does not operate smoothly, it must be replaced with the same

type of valve.

Checking Air Filter Element (Fig. 1)

WARNING: Hot surfaces. Risk of burn. aftercooler, pump head,

and surrounding parts are very hot, do not touch (see the Hot

Surfaces identified in Fig. 2). allow compressor to cool prior to

servicing.
1. Ensure engine START/RUN/OFF switch (C) is in the OFF posi-

tion.

2. Allow unit to cool.
3. Remove filter (A) top from filter base by turning filter counter-

clockwise about 5 degrees.

4. Separate filter top from base.
5. Remove element from filter base.
6. If element needs cleaning, blow out with air. Replace if needed.

Purchase replacement parts from your local dealer or authorized

service center. Always use identical replacement parts.

7. Place element back in filter base.
8. Reconnect filter top to filter base. While pushing in, rotate clock-

wise 5 degrees.

CAUTION: Risk of unsafe operation. Do not operate without air

filter.

Draining Air Tank (Fig. 1)

WARNING: Risk of unsafe operation. Risk from noise. air tanks

contain high pressure air. Keep face and other body parts away from

outlet of drain. Use eye protection [aNSI Z87.1 (CaN/CSa Z94.3)]

when draining as debris can be kicked up into face.

WARNING: Risk from noise. Use ear protection [aNSI S12.6

(S3.19)] as air flow noise is loud when draining.

Advertising