English – DeWalt D55695 User Manual

Page 30

Advertising
background image

30

English

CoDe

PossIble CAuse

PossIble solutIon

22

Engine problem

Contact a D

e

WALT factory service center or a D

e

WALT

authorized service center.

23

Engine or pump oil is low

Add D

e

WALT synthetic compressor oil to pump. See

Compressor Pump oil under Maintenance.

24

Regulator is not adjusted correctly for accessory being

used

It is normal for some pressure drop to occur when an acces-

sory is used, adjust the regulator as instructed in

regulator

under Features if pressure drop is excessive.

note: Adjust the regulated pressure under flow conditions

while accessory is being used.

25

Damaged regulator

Replace.

26

Detergent type oil being used in pump

Drain oil and refill pump with D

e

WALT synthetic compressor

oil.

27

Extremely light duty cycles

Run unit for longer duty cycles. It is recommended to run at

high throttle 50-75% of the run time and idle for 25% of the

run time.

28

Piston rings damaged or worn

Contact a D

e

WALT factory service center or a D

e

WALT

authorized service center.

29

Cylinder or piston damaged or worn

Contact a D

e

WALT factory service center or a D

e

WALT

authorized service center.

30

Compressor cylinder finish worn

Contact a D

e

WALT factory service center or a D

e

WALT

authorized service center.

31

Water in pump oil

Drain oil and refill pump with D

e

WALT synthetic compressor

oil.

32

Manual lock unloader lever in

open position

Rotate manual lock unloader lever to the

closed perpendicu-

lar position.

Advertising