Step 6

Step 7

Turn the PARAMETER SELECT knob one step clockwise to display the Upper Limit

parameter (for PARA 1).

Step 8

Use the PARAMETER ADJUST knob to choose the highest value that the parameter

is not allowed to exceed when the toe of the expression pedal is down.

Step 9

Turn the PARAMETER SELECT knob one step clockwise to access the Lower Limit

parameter (for PARA 1).

Use the PARAMETER ADJUST knob to select the lowest value which the parameter

is not to fall below through when the heel of the expression pedal is down.

NOTE: The UTOPIA B300 allows you to select an upper and lower value limit which the parameter

cannot exceed. For example, if a parameter has a value range from 0 to 127, yet you would like the

range of the parameter to vary from only 50 to 127, you may set a lower limit of 50 and an upper limit

of 127 via the Upper (ULIM) and Lower Limit (LLIM) parameters. When a parameter is stored in the

Pedal Controller function (Step 7), the maximum parameter value is automatically stored as the upper

limit (expression pedal toe down), while the minimum value is stored as the lower limit (expression

pedal heel down).

p e d a l c o n t r o l e r s

u l i m c 1 1 0 0

8. Pedal Controllers......continued.............

p e d a l c o n t r o l e r s

u l i m c 1 1 2 7

p e d a l c o n t r o l e r s

u l i m c 1 0

p e d a l c o n t r o l e r s

u l i m c 1 5 0

NOTE: Parameters available to be assigned may vary depending on what MODULATION effect you have selected for that

particular preset.

NOTE: Because character space on the display is limited, you may not see the entire name of a parameter. For example,

to choose FLANGER LEVEL 1 or FLANGER PAN 1 (or any of the Flanger's parameters), select "LEVEL 1" or "PAN 1"

parameter that immediately follows the "FLANGER" parameter when turning the PARAMETER ADJUST knob clockwise.

This is true for some other parameters as well.

Advertising