Chapter 3: Configuring the 1762sc-OF8 for RSLogix 500

3-9

User’s Manual Pub. 0300246-01 Rev. B

Table 3-7 (Response Codes)

Name Value

Description

Success

0x0000 The command was completed successfully.

Invalid Command 0xF001 An invalid command code was issued.

Locked 0xF002

A command was issued before the Unlock was
given.

Invalid State

0xF003

One or more Fixed Words invalid. The module will
remain in its previous state until all of the words
are set correctly.

Invalid Config

0xF004

A configuration for one of the channels is invalid.
Check Response Channel to determine which one.
First error detected is displayed.

No Config

0xF005

An attempt was made to exit Command Mode
before a configuration was loaded. Either load the
default config or manually enter a configuration for
all channels.

Invalid Cal

0xF006

Calibration is invalid. Module requires factory
calibration before it can be configured.

Note: Response codes are not be considered valid until the Command
Echo matches the issued command.

Note: Response codes will remain valid after the Exit command until the
timeout expires. After that, normal Input File operation takes over. Words 0-
2 are status.

3.5.2 Input Data File (Normal Run Mode)

In normal run mode, the input data file displays general module status, channel status and
an echo of each channel configuration.

Use the addressing scheme in Figure 3-3 to locate the 8 input words.