VERSATEC BASE SERIES 50Hz INSTALLATION MANUAL

Horizontal Dimensional Data cont.

Disconnect Located on this
Side for a Left Return

Disconnect
Location

Horizontal Shown

In Right Return

Configuration

Power Supply

KK

Horizontal Models

KK

005

[20.8]

006-007

[20.8]

009

[23.4]

010-012

[23.4]

015

[28.4]

017

[25.9]

Dimensions in [cm]

Horizontal Disconnect

When using disconnect, do not use dimension K from the
standard horizontal dimensional data. Use dimension KK
from the horizontal disconnect dimensional data.

Horizontal

Models

Overall Cabinet

Water Connections

Electrical Knockouts

1

2

3

Loop

J

K

A

B

C

D

E

H

1/2” (1.27cm) cond

1” (2.54cm) cond

Width

Depth

Height*

In

Out

Condensate

Water FPT

Low Voltage

Power Supply

005

cm.

57.2

88.9

43.7

4.6

17.3

2.0

19.05 mm

18.0

18.0

006-007

cm.

57.2

106.7

43.7

4.6

17.3

2.0

19.05 mm

18.0

18.0

009

cm.

57.2

106.7

48.8

4.6

17.3

2.0

19.05 mm

23.4

18.0

010-012

cm.

57.2

114.3

48.8

4.6

17.3

2.0

19.05 mm

23.4

18.0

015

cm.

64.8

121.9

53.8

4.6

17.3

2.0

25.4 mm

23.4

23.1

017

cm.

64.8

134.6

53.8

4.6

17.3

2.0

25.4 mm

23.4

23.1

Horizontal

Models

Discharge Connection

duct fl ange installed (±0.25 cm)

Return Connection

using deluxe fi lter rack option (±0.25 cm)

Unit Hanger Dimensions

PVC Size

L

M

N

P

Q

R

S

T

U (A)

V (B)

W (C )

X

Supply

Width

Supply

Depth

Return

Depth

Return
Height

005

cm.

14.5

26.7

23.9

12.4

41.7

36.8

5.1

3.6

90.9

63.8

54.4

1.9

006-007

cm.

14.5

26.7

23.9

12.4

59.4

36.8

5.1

3.6

108.6

63.8

54.4

1.9

009

cm.

17.0

26.7

23.9

12.4

69.6

41.9

5.1

3.6

108.7

63.8

54.4

1.9

010-012

cm.

10.7

34.5

33.5

6.1

77.2

41.9

5.1

3.8

116.3

63.8

54.4

1.9

015

cm.

12.2

34.5

33.5

11.7

89.9

47.5

5.8

3.3

124.0

71.4

62.0

1.9

017

cm.

12.2

34.5

33.5

11.7

102.6

47.0

5.8

3.6

136.7

71.4

62.0

1.9

12/5/14

Horizontal units shipped with standard 2” (5.1 cm) (fi eld adjustable to 1” (2.55 cm)) open application fi lter rack extending 2.2” (5.6 cm)
from unit and is not suitable for duct connection. For ductable return connection applications, order the deluxe 2” (fi eld adjustable to 1”) duct
collar/fi lter rack which extends 3.25” from the unit and is suitable for duct connections.