Function description

4

4000

Function description

Function description

4-

Funktionsbeschreibung_allgemein_BAWS

The operating mode selector switch enables you to switch between 5

different operating modes. Operating modes OM1 ... OM4 plus a special

service mode (OM5.)

For OM1 ... OM4, one button each is available. For the special service

mode (OM5), button 1 must be operated for a certain time period (see

Time monitoring -> Operating time). Each button is assigned a moni-

tored semiconductor output. Operating the button changes the semi-

conductor output from low to high. The semiconductor outputs must be

evaluated via a safety control system. The operating mode selector

switch guarantees that only one of the semiconductor outputs is high at

any one time.

Block diagram:

User Interface

RFID

Receiver

=

=

A1

A2

OM 1

Actuator

OM 2

OM 3

OM 4

OM 5

SI0

SI1

SI2

SI3

IDsync

IDclock

IDo0

IDo1

IDi0

IDi1

Input

Power