7-3

7.2

Time monitoring

7

Operation

7.2

Time monitoring

7200

Time monitoring

7-

Zeitüberwachung BAWS

A change of operating modes is only detected once a button has been

operated for a certain time period.

Operating time:

OM1, OM2, OM3, OM4: > 50 ms and < 5 s

Special mode (service) OM5: > 5 s and < 10 s

When a button is released, the semiconductor outputs will switch once

the switchover delay t1 has elapsed (see Technical details).

When changing operating modes, the PIT m3.1p initiates a defined

pause of 50 ms to guarantee that the operating modes do not overlap.

To select an operating mode, follow the instructions below:

Select an operating mode by pressing one of the four buttons. The ac-

tuator must be connected to the operating mode selector switch for the

whole time the button is operated; it can be removed afterwards.

t1

t1

OM5

OM1

OM2

OM3

OM4