Guidelines for jtag bst, Guidelines for jtag bst -1 – Altera MAX 10 JTAG User Manual

Page 13

Advertising
background image

Guidelines for JTAG BST

6

2015.05.04

UG-M10JTAG

Subscribe

Send Feedback

Consider the following guidelines when you perform BST with the device:
• If the “10...” pattern does not shift out of the instruction register through the

TDO

pin during the first

clock cycle of the

SHIFT_IR

state, the TAP controller did not reach the proper state. To solve this

problem, try one of the following procedures:
• Verify that the TAP controller has reached the

SHIFT_IR

state correctly. To advance the TAP

controller to the

SHIFT_IR

state, return TAP controller to the

RESET

state and send the

01100

code

to the

TMS

pin.

• Check the connections to the

VCC

,

GND

,

JTAG

, and dedicated configuration pins on the device.

• Perform a

SAMPLE/PRELOAD

test cycle before the first

EXTEST

test cycle to ensure that known data is

present at the device pins when you enter

EXTEST

mode. If the

OEJ

update register contains 0, the data

in the

OUTJ

update register is driven out. The state must be known and correct to avoid contention

with other devices in the system.

• To perform testing before configuration, hold the

nCONGFIG

pin low.

©

2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134

Advertising