Software instructions, Software instructions –6 – Altera ByteBlasterMV User Manual

Page 24

Advertising
background image

2–6

Altera Corporation

Software Instructions

Software
Instructions

The Altera Quartus II design software package provides the programmer
function required to configure or program devices using the ByteBlasterMV
download cable.

To configure or program one or more devices with the ByteBlasterMV cable and
the Quartus II Programmer, perform the following steps.

f

For a detailed explanation of the programming process, see the Programming
module of the Quartus II tutorial. See also the “Overview: Working with Chain
Description Files” and “Overview: Converting Programming Files” topics in
Quartus II Help.

1.

Compile a project. The Quartus II Compiler generates a programming file,
such as a SOF, a POF, a Jam File (.jam), or a Jam Byte Code File (.jbc),
depending on the target device.

Table 2–6. ByteBlasterMV Cable DC Operating Conditions

Symbol

Parameter

Conditions

Min.

Max.

Unit

V

IH

High-level input voltage

V

C C

= 5.5 V

2.32

V

V

C C

= 3.6 V

1.53

V

V

C C

= 2.625 V

1.11

V

V

C C

= 1.89 V

0.80

V

V

IL

Low-level input voltage

V

C C

= 4.5 V

1.36

V

V

C C

= 3.0 V

0.89

V

V

C C

= 2.375 V

0.71

V

V

C C

= 1.71 V

0.51

V

V

OH

5.0-V high-level output voltage

V

C C

= 4.5 V, I

OH

= 8 mA

4.4

V

3.3-V high-level output voltage

V

C C

= 3.0 V, I

OH

= 4 mA

2.9

V

2.5-V high-level output voltage

V

C C

= 2.375 V, I

OH

= 2 mA

2.275

V

1.8-V high-level output voltage

V

C C

= 1.71 V, I

OH

= 2 mA

1.61

V

V

OL

5.0-V low-level output voltage

V

CC

= 5.5 V, I

OL

= 8 mA

0.125

V

3.3-V low-level output voltage

V

CC

= 3.6 V, I

OL

= 4 mA

0.125

V

2.5-V low-level output voltage

TTL load. V

CC

= 2.625 V,

I

OL

= 2 mA

0.125

I

CC

Operating current (no load)

50

mA