background image

Value of tsdcalo[7:0] in Hexadecimal

Temperature in Degree Celsius (°C)

...

...

6C

-20

...

...

62

-30

...

...

4E

-50

...

...

3A

-70° C

Altera Temperature Sensor Prototypes and Component Declarations

Verilog HDL Prototype

The Verilog HDL prototype is located in the

<Quartus II installation directory>\eda\synthesis\ altera_mf.v

VHDL Component Declaration

The VHDL component declaration is located in the <Quartus II installation directory>\libraries\vhdl

\altera_mf\ directoryaltera_mf_components.vhd.

Document Revision History

This table lists the changes made to the document.

Table 7: Document Revision History

Date

Document

Version

Changes Made

May 2015

2015.05.04 • Added a link on how to calculate the temperature from the

tempout[9:0]

value.

• Editorial updates.

December 2014

2014.12.15 • Added Arria 10, Arria V, and Arria V GZ devices to the Device

Support section.

• Editorial changes to the warning message in Temperature

Sensing Operation section.

• Added Arria 10 devices information.

• Updated template.