5 standard barometric pressure sensor, Standard sensors, 2 solarimeter - sensus channel configuration – Casella CEL Automatic weather station User Manual

Page 23: 3 sunshine duration

Advertising
background image

Output calibration:

Typically 100

µV/W/m², supplied with

individual calibration details

3.4.2

Solarimeter - Sensus Channel Configuration

Description

Solarimeter

Units

W/m

2

Type

Analog

Information

Single ended
Gain x 1
No current source

Display Format

####.#

Polynomial

-27, 11990.4
(sensor specific)

Enabled

Yes

Logged

Yes

Minimum Limit

0.0

Maximum Limit

2000.0

3.4.3

Sunshine Duration

The Sensus Logger can determine daily Sunshine hour values. The accumulated
total is determined based upon the time during which the solarimeter has been
exposed to a radiation level exceeding a threshold of 200 W/m².

3.5

Standard Barometric Pressure Sensor

The weather station may be fitted with a
standard integral barometer mounted on a
circuit board in the data logger, which itself is
inside the environmental case. A 1 mm
ventilation hole in the case ensures the
internal pressure remains at ambient.

A monolithic silicon transducer

senses pressure by means of a silicon
diaphragm into which a “bridge” of piezo
resistors have been defused.

3.5.1

Standard Barometric Pressure Sensor Specification

Part number:

183014B

Transducer:

The pressure sensor is temperature stabilised
at 60

o

C

Range:

800 to 1100 hPa (mB)

Operating temp:

-40°C to + 85°C

Accuracy:

<1 hPa (mB)

Temperature drift:

Typically <0.15 mB/°C

Supply voltage:

9 - 12 V nominal

Power consumption:

Approx. 10 mA at 12 V

Standard Sensors

The standard pressure sensor
board in the Sensus Logger

Page 23 of 34

Automatic Weather Station
Assembly & Commissioning Handbook

Advertising