CVM-NRG96

M9817250120-03-05A

25

Once the Alarm Condition code has been selected and the data entered
using the

key

,

the maximum value, minimum value and the delay

(hysteresis) for the alarm condition must be entered.




-

Hi:

Maximum value; transistor closed above this value.

-

Lo:

Minimum value; transistor closed below this value.

-

Delay: Delay in seconds from the connection and disconnection

of the transistor.

To write or change the maximum and minimum values, the MAX key has to
be pressed, increasing the value of the digit flashing at the time.
When the required value is on the screen, move on to the following digit by
pressing MIN, to allow the remaining values to be changed.
When the last digit has been changed, press MIN to move back to the first
digit, allowing the previously set values to be changed again.
In order to enter one of the data, press the

key moving on to the next

setting step. Once the delay has been set, the

key must be pressed

entering the data and ending the configuration.

MIN +

MAX +

max > min

ON OFF ON

======

0 Min Max

MIN +

MAX +

max < min

OFF ON OFF

====

==========

0 Max Min

MIN --

MAX +

ON OFF ON

=======

Min 0 Max

MIN +

MAX --

OFF ON OFF

=======

======

Max 0 Min

MIN --

MAX --

max > min

ON OFF ON

=====

Min Max 0

MIN --

MAX --

max < min

OFF ON OFF

=====

===========

Max Min 0

* The alarms depend on the preset values: MAXIMUM and MINIMUM