7.7.

Bi-directional Serial RS-232/422/485
with Power 24 VDC

Overview

This bi-directional serial channel is used for RS-232, RS-422 and RS-485 communication and for power supply
24 VDC and it is applicable for ipCUE sigma SERIAL 1. Maximum speed is 115 200 Bd (bps). Default mode for
all channels is RS-232, other modes must be set in programming application. For more details see
programming manuals.

This channel is not applicable for ipCUE-alpha, ipCUE-beta, ipCUE-gamma, ipCUE-delta, ipCUE-epsilon.

RS-232 Mode

Output signal levels for RS-232 are in the -10 V to +10 V range. This is default mode.

Connector pin out

User Manual ipCUE Controllers

www.cuesystem.com

Page 21 of 52

Pin

1
2
3
4
5

Signal

TxD

RTS

GND

RxD

CTS

Description

RS-232 Transmitted Data
RS-232 Request to Send
Ground
RS-232 Received Data
RS-232 Clear to Send

Note

From ipCUE
From ipCUE

To ipCUE
To ipCUE

7-pin 3.5 mm

RS-232 with power 24VDC

+24

+24

Power +24VDV

G

GND

Ground

\

1

2

3

4

5

+24 G