Put back the cover.

9.

Press the ON/OFF button off and then back on. Nor-

10.

mal operation of the burner should return.
Allow the burner to operate for a minimum of five

11.

minutes.

RM2351, RM2451, RM2551, DM2652 & DM2852

To test the gas safety shut off, follow these steps:

Start the refrigerator without connecting to

1.

120V AC.
Check that the gas flame is lit. In AUTo mode,

2.

the AUTo mode indicator lamp is on.
Follow steps 3-11 in the previous instruction.

3.

electrical connection

120 V aC connection

The refrigerator is equipped with a grounded three-prong plug

for protection against shock hazards. It should be plugged di-

rectly into a properly grounded three-prong receptacle. Do not

cut or remove the grounding prong from this plug!
The free length of the cord is 2 feet. It should be routed to

avoid direct contact with the burner cover, flue cover or any

other components that could damage the cord insulation.
To allow easy access through the vent door, it is recommended

that the receptacle is placed like this:

RM2351 & RM2354

To the left of the refrigerator and 4-6” above the refrigerator

mounting floor

RM2451, RM2454, RM2551, RM2554, DM2652 &

DM2852

To the left of the refrigerator and 6” above the refrigerator

mounting floor

DM2662, DM2663, DM2862, DM3862 & NDM1062

To the left of the refrigerator and 3” above the refrigerator

mounting floor.

NDR1292

To the right of the refrigerator and 10” above the refrigerator

mounting floor.

12V dC connection

RM2451, RM2551, DM2652 & DM2852

: These refrigerator

models are not designed for 12V DC operation of the cooling

system. However, 12V DC must be supplied to operate the

controls.

RM2354, RM2454, RM2554, DM2662, DM2663, DM2862,

DM3862 & NDM1062

: These refrigerator models require a

continuous 12V DC supply to maintain the automatic energy

system.
The connection is made to the positive (+) and negative (-)

terminals of the terminal block on back of the refrigerator.
Correct polarity must be observed when connecting to the DC

supply. Do not use the chassis or vehicle frame as one of the

conductors. Connect two wires at the refrigerator and route to

the DC supply. Ensure the connections are clean, tight and free

from corrosion.
Ensure that the wires from the battery to the refrigerator are

able to handle the load. The distance the current must travel

from the battery to the refrigerator dictates the AWG wire size

to be used. Inadequate wire sizes can result in a voltage drop

which affects the refrigerator performance.
For 3-way models, the voltage drop affects the wattage output

of the 12V cartridge heater and the refrigerator performance.

The 12V DC heater is fused with a 30 amp. in-line blade fuse.

Recommended wire sizes are displayed in the following table:

MaxiMuM total ConduCtor wire length

wIRe

MODeL

Size

Length

AWG

ft

m

RM2351

RM2451

RM2551

DM2652

DM2662

DM2852

DM2862

DM3862

NDM1062

NDR1292

14
12

17
27

5
8

RM2354

RM2454

RM2554

DM2663

10

8

17
27

5
8

NDR1292

120 Volt AC

receptacle

120v AC

receptacle

3”

4-6”

6”

10”

120v AC

receptacle

RM2451, RM2454, RM2551,

RM2554, DM2652, DM2662,

DM2663, DM2852, DM2862,

DM3862 & NDM1062