Maintenance & service, Periodic maintenance checking the control system, Checking the connections – Dometic DM2862 User Manual

Page 23: Checking the lp gas pressure, Cleaning the flue baffle and burner, Warning

Advertising
background image

- 23 -

peRioDic MaiNteNaNce
Checking the control system

Check the control system by connecting/disconnecting the

120V AC power, starting/stopping the engine, etc.

Checking the connections

Check all connections in the LP gas system (at the

1.

back of the refrigerator) for gas leaks. The LP gas

supply must be turned on.
Apply a non-corrosive bubble solution to all lP gas

2.

connections. The appearance of bubbles indicates a

leak and should be repaired immediately!

Checking the lP gas pressure

The LP gas pressure should be checked and the main regulator

readjusted if pressure is incorrect. The correct operating pres-

sure is 11 inches of water column. Measure the LP gas pressure

at the test port, just ahead of the burner jet.

Cleaning the flue baffle and burner

Inspect the flue baffle. It should be reasonably clean and free

of soot. Heavy soot formation indicates improper functioning

of the burner.
To clean the flue and burner, follow these steps:

Turn off the refrigerator.

1.

Unplug the power cord from the 120V AC outlet.

2.

Disconnect the wires or shut off the 12V DC power

supply to the refrigerator.
Turn off the manual shut off valve.

3.

Remove cover from burner housing. Remove the

4.

burner mounting screws and then, the burner as-

sembly.

Remove the wire and flue baffle from the top of the

5.

flue tube.
Using a flue brush, clean the flue from the top. Blow-

6.

ing compressed air into the flue will not properly

clean soot and scale out of the flue tube.
Put back the flue baffle.

7.

Clean the burner tube with a brush. Blow out the

8.

burner with compressed air.

Remove burner jet, but first, clean burner area of

9.

soot and scale that fell out of flue tube.
Remove the burner jet.

10.

Soak the jet in wood alcohol and blow it out with

11.

compressed air.
R

12. einstall and tighten the burner jet.

Reinstall the burner. Ensure the end of the burner fits

13.

into the slot on the burner bracket. Verify that the

slots are centered under the flue tube and the thermo-

couple is positioned properly (tip of thermocouple

extends over two slots of burner).

Check the electrode for proper location and gap.

14.

Turn on the manual gas shut off valve.

15.

Examine all fittings for leaks. (Use a commercial

16.

non-corrosive bubble solution.)
Connect the 120V power cord. Reconnect/turn on

17.

the 12V DC power.
Check the LP gas safety shut off.

18.

BURNER TUBE .

SPARK ELECTRODE

BURNER JET

BURNER MOUNTING

SCREWS

PRESSURE TEST PORT

MANUAL SHUT OFF VALVE

(Shown in open position)

INLET FITTING

SOLENOID VALVE

gas equipment assembly

Electrode

Burner tube

1/8” to 3/16”

(3-5 mm)

4HE

maintenance & serVice

wARNINg

eXPLOSION hAZARD. Never use an

open flame to check for gas leaks. Failure

to heed this warning could cause an explo-

sion resulting in death or severe personal

injury.

6

!

wARNINg

FIRe hAZARD. Do not use a wire or pin

when cleaning the burner jet as damage

can occur to the precision opening. Failure

to heed this warning could cause fire result-

ing in personal injury

6

!