Ventilation requirements, Clearances, Ventilation heights – Dometic DM2862 User Manual

Page 5

Advertising
background image

- 5 -

cleaRaNces

Minimum clearances (in inches) to combustible materials:
Top (G)

0

Side (K)

0

Bottom (L)

0

Rear (M

1

)

0 / 1

(

RM2351 & RM2354

)

1

The distance between the rearmost part of the refrigerator and the wall

behind it.

Ventilation heightS

It is essential that all maximum or minimum dimensions

are strictly maintained, as the performance of the refrigerator

is dependent on adequate flow of air over the rear of

the refrigerator.

Minimum ventilation heights

Roof vent and

lower side vent

Upper and lower

side vent

RM2351

RM2354

inches

mm

inches

mm

31

787

34

864

RM2451

RM2454

37-3/4

960

RM2551

RM2554

44-1/2 1130

DM2652

DM2662

DM2663

57-3/4 1465

DM2852

DM2862

DM3862

NDM1062

63-3/4 1620

NDR1292

65

1651

A

B

B

Minimum

ventilation

height

Condenser

A

Condenser

The upper vent

should be centered

over the condenser

coil at the back of

the refrigerator.

Minimum

ventilation

height

M

M

G

K

K

L

SIDe vIew wITh DUCT SySTeM

DM2852, DM2862, DM3862 & NDM1062

Air channel

For installation instructions of the Air Channel, please refer to

INSTAllATIoN oF AIR ChANNEl

”, Rev. 825129100 or later.

Ventilation requirements