WaveWare Call Manager User Manual

Page 27

Advertising
background image

STEP 9 – Register Call Devices – Wireless Inovonics

Configuring the “Inovonics Wireless System Input Port”

Configured for use as a

Universal Transmitter

- “

Terminal

” Device (Ex: Contact Closure)

Choose the “

Inovonics EN Wireless System Input Port

”.

See Fig. 40-2

B

To “

Register Call Devices

” simply “

Trigger

” the Device and wait until you see it on the Screen.

See Fig. 40-2

A

NOTE: Trigger one Device at a time and wait a Few Moments until the System “Acknowledges” the Device.

Fig. 40-2

In this Example the Device is being used with a Contact Medical Device.
This model Universal Transmitter only has a “Terminal” Block, so when the
Device is Triggered and Reset, the Device will send out a Signal to the Central
Receiver which is attached to the Call Manager Software. The Call Manager
Software sends an Alert Message out to the Assigned Msg Recipient (Pager).

Fig. A:

Trigger the Wireless Call
Device and wait a Few
Moments.
The New Device should be
Displayed on the Screen.

After the Device is Shown, you
can Choose:

-The “Device Type”
-The “Room”

Do this for Every Device Type
Registered.

Note:

You can Assign the

Room at a Later time, if you
wish.

Fig. B:

Choose One:

-Call System Input Port
-Inovonics EN Wireless System
Input Port

Here in this Example we are
Working with the

Inovonics

Wireless System

Input Port

to

Register Wireless Call Devices.

Fig. C:

Choose Call Processing:

In this Example the

Universal

Transmitter

is used as a

Contact Closure

.


For this Purpose the

Call

Processing

should be set to

Terminal

” for Both Initiation

and Cancelation.


You can also Assign an

Installer

” Pager, to be used for

Testing during this Time.