Direct Memory Access



Figure 39.

Write-Register Pointing Methods

Write Register 0 Group

The WR0 base register byte is identified by a 0 in bit 7 and any combi-
nation except 0, 0 in bits 0 and 1 (Figure 40). It sets the following condi-
tions.

Class of Operation

Bits 1 and 0 used together set the class of operation as sequential transfer
(0,1), search only (1,0), or sequential/transfer/search (1,1). Simultaneous
transfers or transfer/searches are obtained by selecting the search-only
class (1,0) and by allowing the external hardware to generate the appro-
priate bus control signals for the complete transfer (see the chapter
“Applications”).

D7 D6 D5 D4 D3 D2 D1 D0

Base Register

Associated Register #1

Associated Register #2

Associated Register #3

Associated Register #4

Pointer Bits