Group
Name
CmdResp Description
Read
/
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
IN_KEYING_B_LEVEL
KB KB Keying level (Bule)
Rd/Wr0
255 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
IN_KEYING_TOLER
KH KH
Keying Tolerance (for chroma
and luma key)
Rd/Wr0
255 10
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
IN_KEYING_LUMA_LOW_LEVEL KL KL
Minimum luma level
Rd/Wr0
255 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
IN_KEYING_LUMA_HIGH_LEVEL KM KM Maximum luma level
Rd/Wr0
255 255
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12