Analog Way PULSE LE - Ref. PLS200 Programmer's Guide User Manual
Page 25
25
Group
Name
CmdResp Description
Read
/
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
SET_PULLDOWN_3_2
Sp Sp
Enable/disable the auto 3:2
pulldown
Rd/Wr0
1
1
0 = Disable automatic detection
1 = Enable automatic detection
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_CROP_WIN_POS_H
SI
SI
Cropping window horizontal
position
Rd/Wr0
6553532768
Percent = 65535 = 100% : all
cropping on the left
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_CROP_WIN_POS_V
SJ SJ
Cropping window vertical
position
Rd/Wr0
6553532768
Percent = 65535 = 100% : all
cropping on the top
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_CROP_WIN_SIZE_H
SK SK Horizontal cropping
Rd/Wr0
589810
Percent = 65535 = 100%
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12