Group

Name

CmdResp Description

Read
/
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

SIG_HTOTAL_MAXI

sM sM

Maximal number of pixels per
input line

Rd

0

655350

Unit = pixels

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SIG_WIDTH

sw sw

Input displayed pixel count

Rd

0

655350

Unit = pixels

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SIG_HEIGHT

st

st

Input displayed line count

Rd

0

655350

Unit = pixels

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SIG_HDCP

sn

sn

Input HDCP status

Rd

0

1

0

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12

Advertising