Analog Way PULSE LE - Ref. PLS200 Programmer's Guide User Manual

Page 27

Advertising
background image

27

Group

Name

CmdResp Description

Read
/
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

SET_FORCE_4_3

SF SF

Force the aspect ratio of
PAL/NTSC input to 4/3

Rd/Wr0

1

1

1 = forced

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_RESET_SETTINGS

Ss Ss

Current input default settings

Rd/Wr0

1

0

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_FREEZE

Sf

Sf

Freeze of the input

Rd/Wr0

1

0

1 = Freeze

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_MOTION_DETECT

Sm Sm

0 : max correction; 15 : min
correction

Rd/Wr0

15

15

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12