Group

Name

CmdResp Description

Read
/
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

PE_SIZE_V

pS pS

Layer V size on output screen
(without borders)

Rd/Wr0

655351200

Unit = pixels (Max=16x2048 =
32768)

0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4

2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
8 = Audio
Output 1
9 = Audio
Output 2

PE_CROP_WIN_POS_H

CH CH

Cropping window horizontal
position

Rd/Wr0

6553532768

Unit = percent ( 65535 = 100%
= : all cropping on the left )

0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4

2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
8 = Audio
Output 1
9 = Audio
Output 2