Network management and system access – Artesyn Centellis 2000 Shelf - DC Installation and Use (June 2014) User Manual

Page 133

Advertising
background image

Network Management and System Access

Centellis 2000 Shelf - DC Installation and Use (6806800G45F)

133

Virtual Standby IP Address on Out-of-Band Interface

To avoid an address conflict between out-of-band and backplane interfaces, 100 is added to
the third octet of all out-of-band interface IP addresses, if any of them would be equal to one of
the backplane addresses otherwise.

Changing the Shelf Manger Virtual IP Address for the Out-of-Band Interface

To change this IP address, you must modify the first two octets of the Shelf IP Connectivity
Record #1 and/or change the shelf address. Refer to

Setting the Shelf Geographical Address

on

page 129

to see how you can change the shelf address. This procedure describes how to

change the first two octets of the IP address.

1. Change the first two octets of the IP address using the hpiship tool located on the

shelf manager. Use the option -h for help.

2. Reboot the system for the changes to take effect.

Example #1:

Print current IP address settings and change out-of-band address:

*Print current IP address settings

shm9s8:~ # hpiship

29 {ADVANCEDTCA_CHASSIS,9} Shelf Resource

4097 Shelf Manager IP Address 0

IP : 192.168.9.171

Gateway: 192.168.9.0

Submask: 255.255.255.0

Netmask of IP1

Virtual Standby IP Address

Default Value

255.0.0.0

<IP1_1>.<IP1_2>.<SGA>.181

192.168.0.181

255.255.0.0

255.255.255.0

Advertising