100-01178

4081029

Alcove Installation Requirements

Whenever the stove is placed in a location where the ceiling height is less than 7' (2134mm) tall, it is
considered an alcove installation. Because of the reduced height, the special installation requirements
listed below must be met.
 Chimney connector and chimney must be one of the following types:

AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Standard Masonry Chimney with any one of the above listed connectors

NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.

 Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have walls

and a ceiling that are 3 1/2" (89mm) thick of a non-combustible material (brick, stone, or concrete -
see Figure 9). This non-combustible material must be spaced and ventilated at least 1" (25mm) from
all combustible materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls
and ceiling. All other alcoves are considered combustible. The clearances below must be met:

Minimum Clearance
(See the
Figure 9 below)


Combustible Alcove


Non-Combustible Alcove

A

Sidewall to stove

18"

457mm

8"

203mm

B

Backwall to stove

10-1/2"

267mm

2"

51mm

D

Connector to sidewall

26-1/2"

673mm

16-1/2"

419mm

E

Connector to backwall

11-1/4"

286mm

2-1/2"

64mm

G

Maximum depth of alcove

48”

1219mm

48"

1219mm

H

Minimum width of alcove

59-5/8"

1514mm

39-5/8"

1006mm

J

Minimum height of alcove

84"

2134mm

6" (152mm) above
stovetop

Figure 9

Non-combustible alcove
construction (on walls
and ceiling) - see the
explanation above.

Min. 3 1/2"
(89mm) non-
combustible
material

Combustible

materials

1" (25mm)
Min.

Ventilated
air space

Non-combustible
reinforcer

A

B

D

E

H

G

J

Advertising