3 power supply and fan module leds, Power supply and fan module leds – Dot Hill Systems II 200 FC User Manual

Page 107

Advertising
background image

Chapter 6 Checking LEDs

6-9

The I/O expansion module LEDs and their color definitions are shown in Table 6-5.

Note –

An SFP link status (L) LED is off if there is no connection or a failed

connection to this SFP.

6.3.3

Power Supply and Fan Module LEDs

The following figure shows the AC power supply and fan module.

Table 6-5 I/O Expansion Module LEDs

LED

Purpose

LED Color Definition

Activity

I/O activity of host
and disk ports

Off – Not busy (no I/O activity)
Blinking green – Busy (active I/O)

I/O module

Status of I/O
module

Solid green – Power-up successful and SES
chip has successfully read on-board
temperature and voltage sensors
Amber – Expansion unit powering up, or
failed voltage or temperature sensor
Off - Expansion unit is not powered up

SFP link (L)

SFP link status

Solid green – Active good FC Connection
Off – Empty or failed FC connection

SFP speed (S)

SFP speed status

Solid green – 2 Gbit
Off – 1 Gbit

Table 6-6 Power Supply LEDs

Purpose LED

LED

Color

Definition

Monitors the DC output voltage
within tolerance specification.
Overcurrent protection shutting down
any voltage output is also displayed.
Voltage thresholds:
+5 VDC +/–.25 VDC
+12 VDC +/–.6 VDC
Current thresholds:
+5 VDC 35A
+12 VDC 25A

Solid green

Solid amber

Power supply and fans are
good.

Failed: One or more output
voltages out of range or one
or both fans is rotating at less
than 4000 RPM.