Figure 8-6 front-panel leds flowchart, 1 of 4, Chapter 8 troubleshooting your array 8-17 – Dot Hill Systems II 200 FC User Manual

Page 135

Advertising
background image

Chapter 8 Troubleshooting Your Array

8-17

Figure 8-6 Front-Panel LEDs Flowchart, 1 of 4

3A

Front panel LEDs problem (FC)

All

front panel

LEDs flashing

amber?

Yes

LEDs stop

flashing?

No

Are all the

LEDs off during

operation?

Is the power

switch on?

Yes

No

Is the power

connected?

Is the

power cord

well seated?

Resolved?

Yes

Yes

Yes

Turn it on.

No

Connect it.

No

Seat it.

No

Yes

No

No

Replace chassis.

Continue with

3B.

Adjust end cap to ensure
reset button is not depressed.

Remove the right end cap.

Check that the Reset button
is not jammed.

Check that LED ribbon cable
in right ear is not loose.

Replace the end cap.

Yes

Refer to

FRU Installation

Guide for

instructions

No

Is the LED

ribbon cable on the

right ear loose?

Secure the

ribbon cable.

Replace chassis.

Yes

End

End

--Reseat the FRU that is not operating correctly.

--Swap the questionable FRU with a known-good
FRU from the same array.

Notes
Prior to replacing a chassis, try the following:

Advertising