5 the veritas volume manager asl, 2 battery operation, 1 battery status – Dot Hill Systems II 200 FC User Manual

Page 112: The veritas volume manager asl, Battery operation, Battery status

Advertising
background image

7-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

7.1.5

The VERITAS Volume Manager ASL

VERITAS has provided an Array Software Library (ASL) that must be installed on the
same host system as the Volume Manager 3.2 or 3.5 software to enable the software to
recognize a FC or SATA array.

7.2

Battery Operation

The battery LED (on the far right side of the I/O controller module) is amber if the
battery is bad or missing. The LED blinks green if the battery is charging and is solid
green when the battery is fully charged.

7.2.1

Battery Status

Battery status is displayed at the top of the initial firmware screen. BAT: status
displays somewhere in the range from BAD to ----- (charging) to +++++ (fully
charged).

For maximum life, lithium ion batteries are not recharged until the charge level is very
low, indicated by a status of -----. Automatic recharging at this point takes very little
time.

A battery module whose status shows one or more + signs can support cache memory
for 72 hours. As long as one or more + signs are displayed, your battery is performing
correctly.

Table 7-1 Battery Status Indicators

Battery
Display

Description

-----

Discharged; the battery is automatically recharged when it reaches this
state.

+----

Adequately charged to maintain cache memory for 72 hours or more in
case of power loss. Automatic recharging occurs when the battery
status drops below this level.

++---

90% charged; adequate to maintain cache memory for 72 hours or
more in case of power loss.

+++--

92% charged; adequate to maintain cache memory for 72 hours or
more in case of power loss.

++++-

95% charged; adequate to maintain cache memory for 72 hours or
more in case of power loss.

+++++

Over 97% charged; adequate to maintain cache memory for 72 hours
or more in case of power loss.

Advertising