Ecm motor connections – Boyertown Regal Oil Furnace Nrg Max User Manual

Page 11

Advertising
background image

11



















ECM Motor Connections

\

The operation of the motor requires two main connections: the power input connector which is 120VAC,
and the signal input connector from a 24VAC thermostat. Figure 1 shows the location of the connectors
on the motor. When wiring your ECM, the pin
locations are crucial in assuring that no damage is
done to the motor or the control. The figures show
the pin locations for both connectors, when viewing
the motor as shown below







ECM REH/REL 750 Heating Speed Selection

Burner
Firing Rate

Heat Switch

#1 Position

Heat Switch

#2 Position

Program Heating

Air Flow

0.60 GPH

ON

ON

D

950 CFM

0.75 GPH

OFF

OFF

A

1175 CFM

0.85 GPH

ON

OFF

B

1325 CFM

ECM REH/REL 1000 Heating Speed Selection

Burner
Firing Rate

Heat Switch

#1 Position

Heat Switch

#2 Position

Program Heating

Air Flow

1.00 GPH

ON

ON

D

1575 CFM

1.25 GPH

OFF

OFF

A

1925 CFM

ECM REH/REL 750 Cooling Speed Selection

AC
Tons

Cool Switch

#1 Position

Cool Switch

#2 Position

Program Cooling

Air FlowY2

Cooling

Air FlowY1

Air Flow

“G”

4 Tons

OFF

OFF

A

1600 CFM

1200

800

3 Tons

ON

OFF

B

1200 CFM

900

600

2-1/2 Tons

OFF

ON

C

1000 CFM

750

550

2 Tons

ON

ON

D

800 CFM

600

550

ECM REH/REL 1000 Cooling Speed Selection

AC
Tons

Cool Switch

#1 Position

Cool Switch

#2 Position

Program Cooling

Air Flow Y2

Cooling

Air FlowY1

Air Flow

“G”

5 Tons

OFF

OFF

A

2000 CFM

1500

1000

4 Tons

ON

OFF

B

1600 CFM

1200

800

3 Tons

OFF

ON

C

1200 CFM

900

600

2-1/2 Tons

ON

ON

D

1000 CFM

750

550

Signal Connector
Pin Description
1 C1
2 W/W1
3 C2
4 DELAY
5 COOL
6 Y1
7 ADJUST
8 OUT-
9 O
10 BK/PWM
11 HEAT
12 R
13 EM/W2
14 Y/Y2
15 G
16 OUT+

Power Connector
Pin Description
1

JUMPER PIN 1 TO PIN 2

2

120 VAC LINE INPUT

3 CHASSIS

GROUND

4 AC

LINE

5 AC

LINE

Signal
connector

Power
connector