33

Installation and Service Check List

Furnace Model: _______________________

Serial No.: ______________________

Installation Date: ______________________
Installer Name: ________________________

Phone No.: ______________________

Furnace Installation

Furnace level and in solid contact with floor?

Furnace and burner wired per wiring diagram and National Electric Code? 120VAC wiring Type_____ Size _____

Burner sealed to furnace? Mounting nuts tight?

Space is large enough to provide required clearances?

NFPA 31 Installation of Oil Burning Equipment followed?

Local, state and national codes, laws, regulations and ordinances followed?

Vent System

Existing chimney and vent system inspected to NFPA 211 and in good condition?

New vent pipe installed and properly sealed?

Vent size checked against furnace manual and codes?

Duct Work

Return and supply ducts checked for size based on furnace air flow and ACCA Manual D?

All ducts sealed and insulated as required?

Burner Operation

Burner Model: __________________ Nozzle: _______GPH _______Deg. _______Type_______

Burner Pump Pressure: ______________

Fuel filter and fuel lines installed and inspected as per burner manual?

Air bled from oil piping? Piping checked for leaks?

Burner started, adjusted and tested per burner manual?

Furnace Operation

Thermostat heat anticipator set per burner manual instructions?

Temperature rise through the furnace checked 75

0

F maximum and blower speed adjusted as required?

Blower motor amperage does not exceed rated full load amperage?

Clean air filter installed?

Limit control tested for proper operation?

Furnace observed going through several operational cycles for proper operation?

Post Installation

Reviewed owners’ information in this manual with owner and instructed to keep for future reference?

Properly filled in and returned warranty registration card to Boyertown Furnace Co.

Inserted burner manual instructions with furnace manual for future use?