Boyertown Regal Oil Furnace Nrg Max User Manual
Page 16
16
Verify that the electrode settings match the manufacturers recommended settings.
Inspect the combustion chamber. Verify that it is in the correct position in the heat exchanger and is
in good condition.
The oil burner is to be bolted to the pouch plate using the burner mounting flange gasket and the nuts
supplied. Make sure that the burner passes through the burner opening in the combustion chamber and
does not protrude into the combustion chamber. Refer to the wiring section of this manual for the
correct wiring connections to the furnace and to the oil burner manual for fuel piping.
Table 10 Riello Burner Specifications
Furnace Model
Burner
Model
Delavan
Nozzle
Pump
Press.
Air
Setting
1
Turbulator
Setting
Tube
Length
Insertion
REL/REH600
40F3
0.50X60
º
A
150 2.75 3.0 8” 5-1/4”
2
REL/REH750
40F3
0.60X60
º
A
150
4.0
3.0
8”
5-1/4”
2
REL/REH850
40F3
0.65X60
º
A
150 5.25 3.0 8” 5-1/4”
2
REL/REH1000
40F5
0.85X80
º
B
150
2.75
4.0
8-7/8”
7-1/2”
2
REL/REH1250
40F5
1.00X80
º
B
150 3.6 4.0 8-7/8”
7-1/2”
2
Notes: 1. Approximate air settings see start up procedures for final adjustments
2. Burner Amulet Required
Table 11 Carlin Burner Specifications
Furnace Model
Burner
Model
Nozzle Pump
Press.
Air
Band
1
Air Bar
1
Tube
Length
Insertion
REL/REH600
EZ-1
0.60X70
º
A
2
100 0.60 0.60-0.65 7” 5-1/2”
REL/REH750
EZ-1
0.75X70
º
A
2
100
0.75
0.75
7”
5-1/2”
REL/REH850
EZ-1
0.85X70
º
A
2
100 0.85 0.85-1.00 7” 5-1/2”
REL/REH1000
EZ-1
1.00X60
º
SS
3
100
1.00
0.85-1.00
9”
8”
REL/REH1250
EZ-1
1.25X60
º
SS
3
100 1.25 1.10-1.25 9”
8”
Notes: 1. Approximate air settings - see start up section for final adjustments
2. Delavan nozzle 3. Hago nozzle
Table 9 Beckett Burner Specifications
Furnace Model
Burner
Model
Delavan
Nozzle
Pump
Press.
Air
Band
1
Air
Shutter
1
Head Tube
Length
Insertion Static
Plate
REL/REH600
AFG
0.60X80
º
A
100
0
4
F-3
2
6-1/2”
5-1/2”
3-3/8
REL/REH750
AFG
0.75X80
º
B
100 0 6 F-3
2
6-1/2” 5-1/2” 3-3/8
REL/REH850
AFG
0.85X80
º
B
100
0
9
F-3
2
6-1/2”
5-1/2”
3-3/8
REL/REH1000
AFG 1.00X80
º
B 100 0
5 F-6
2
9” 7-3/4”
3-3/8
REL/REH1250
AFG
1.25X80
º
B
100
0
8.5
F-6
2
9”
7-3/4”
3-3/8
Notes: 1. Approximate air settings, see start up procedures for final adjustments.
2. With ceramic amulet and Stainless Air Tube. 3. Low Firing Rate Baffle installed.