3.4 Start-up

Turn on fluid supply gently. Avoid pressure shocks, and bring the instrument gradually up to the level of the

actual operating conditions. Also switch off fluid supply gently.

3.5 Operating conditions

Each instrument has been calibrated and adjusted for customer process conditions.

Controllers or valves may not operate correctly, if process conditions vary too much, because of the

restriction of the orifice in the valve.

3.6 Instrument performance

3.6.1 Meters

Each meter has a step-response of about 50ms. The special adaptive filtering technique in the CORI-FLOW

detects that the flow is changing rapidly and will decrease filtering immediately so a fast response is

possible. After the flow change the filter will increase to get a steady signal.

3.6.2 Controllers

The dynamic response of a controller is factory set. Standard settling-time is defined as the time to reach the

setpoint (and stay) within ± 2% of the initial setpoint. The settling time depends on the properties of the flow,

the system pressure and the valve type used. It can vary between 500ms and 3 seconds.

The control mode is factory set in such a way that after a stepwise change in the flow, there will be little

overshoot.

3.7 Manual operation

By means of manual operation of the push-button switch (#) some important actions for the instrument can

be selected/started. These options are available in both analog and BUS/digital operation modes.

(See also manual operation in document number 9.17.023)

These functions are:

- Reset (instrument firmware-program reset)

- Zeroing

- Restore factory settings (in case of unintentionally change of the settings)

for FLOW-BUS only:

- Automatic installation to FLOW-BUS (installs instrument to free address)

- Remote installation to FLOW-BUS (instruments will be installed by E-7000 or PC-software)

3.8 Analog operation

Digital instruments can be operated with analog signals through the 8-pin circular connector. The

instruments are compatible in use with

analog instruments on this point.

Analog operated instruments, can be hooked up using an 8-wire shielded cable, connected according to the

Bronkhorst Cori-Tech standard.

Each electronic P. C. board is set for one of the following output (and corresponding input) signals:

Signal

output (sensor)

input (setpoint)

code

signal

signal

A

0…5 Vdc

0…5 Vdc

B

0…10 Vdc

0…10 Vdc

F

0…20 mA (sourcing)

0…20 mA (sinking)

G

4…20 mA (sourcing)

4…20 mA (sinking)