Com 1 delay, Print accum, Shows a running total of weights printed. buffer – Digi-Star NT 460 User Manual

Page 39: Set to on pbline, Display unit, Kg unit of measure, Capacity, Only applicable with optional gps) 322, Enter spread width in feet (meters)

Advertising
background image

Menus and Calibration

D3840-US Rev A

NT 460 User’s Manual

35

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

Com 1 Delay

(CI DLY)

221

OFF

,

.10

,.25,.50,

.75,1-5

Printer delay. Set to

higher number for slow

printing.

Print Accum.

(ACCUM)

223

0

Shows a running total of

weights printed.

Buffer

(BUFFER)

238

ON

Set to ON

PBLine

(PBLINE)

239 1,2,

3

Use 3

MENU 3. SCALE CALIBRATION SETTINGS

Display Count

(COUNT)

301 .01,.02,.05,.1,.2,.5,1,2

,5,

10

,20, 50,100

Minimum weight change

that is displayed.

Note:

If this is too small,

scale will be unstable.

Display Unit

(LB-KG)

303

LB

/KG

Unit of measure.

Note:

If this changes,

calibration and set-up

must change.

Capacity

(CAP)

304

85,000

Maximum capacity of

scale.

GPS

Measurement

Unit Value

[AUNIT]

(only

applicable

with optional

GPS)

322

ENGLISH, METRIC

GPS values entered in

English or Metric units.

Rate

[RATE]

323

1.X

Enter desired rate in

tons/acre

(tonnes/hectare).

Width

[WIDTH]

324

40.X

Enter spread width in feet

(meters).

Advertising