Installation
D3840-US Rev A
NT 460 User’s Manual
41
Connect Load Cells to J-Box
J-Box Connections
Connect load cell
wires to terminal
blocks. See Wire
Color Key
J-Box Illustrated for 4
Load Cell Installation
Tighten Nuts
Load Cell Cable
J-Box Cable
Connect to Indicator
bottom Panel.
Wire Color Key
Color
Description
1 White Signal
+
2 Green Signal
-
3 Red
Excitation
+
4 Black
Excitation
-
5 Shield Shield