Re-Calibrating your Scale

D3840-US Rev A

NT 460 User’s Manual

37

RE-CALIBRATING YOUR SCALE

To re-calibrate your scale and make it even more accurate, document at

least 3 to 6 loads of varying sizes and measure the actual weight of all

loads on a certified scale.

Weigh the load immediately before unloading and immediately

after unloading to minimize errors due to changes in fuel etc.

In this example, we are unloading six carts of nutrient onto four semi-

trucks.

Example:

Indicator Certified

Weight

Scale

Weight

Cart Load A

33660

33900

Cart Load B

33240

33540

Cart Load C

35200 35480

Total

Weight 102100

102920

Reading Too High

If the Indicator is reading higher than the certified scale, then the

calibration number is high and should be decreased proportionally. See

page 38.

Reading Too Low

If the Indicator is reading lower than the certified scale, then the calibration

number is low and should be increased proportionally. See page 38.

Advertising