Scale Kit Mounting Installation - 24 Row

8

Case IH Planter Scale

D3870-US Rev B


6. Mount RH bottom bracket with supplied U-bolts 5/8” x 7-3/4” and 5/8” top lock flange. Insert part

number 400525 Cell-2-1/8” DW with 11 foot cable into bottom bracket and secure with 3/4” x 3-1/2” bolt
and 3/4” lock nut. The short end of load cell is installed in the bottom bracket; the long end is installed
in the top bracket. IMPORTANT: Load cell
arrow decal must point UP.

7. Bolt the top load cell bracket and support

bracket together. With 5/8” x 7.0 bolt and 5/8”
top lock flange nut. The two existing planter
frame legs are bolted between the top bracket
and 4 x 2 x 34” tubing. The top bracket needs
to be adjacent to the frame under the catwalk.

8. Repeat the same procedure for the left side

load cell.








Front Bracket





























Advertising