Connect load cell and j-box cable, Installing wires into terminal block – Digi-Star Case IH 1250 - 12/16/24 User Manual

Page 12

Advertising
background image

Junction Box Mounting

10

Case IH Planter Scale

D3870-US Rev B

JUNCTION BOX MOUNTING

The junction box is water resistant, not water-proof. It should be mounted to avoid submersion during wet

weather and to avoid physical abuse. The junction box can be mounted on the front or rear of the drill,

planter or seeder. All load cell cables must reach the J-Box. Install by removing the double sided tape

backing and apply to cleaned surface.

Connect Load Cell and J-Box Cable

1. Route front and rear load cell cables to J-box location.

Make sure they are not bound or pinched. Cable tie

(customer provided) load cell cables in place.

2. Insert load cell and J-box cables through each of the

water-tight strain-reliefs.

3. Remove each terminal block from the J-box.

4. Connect wires of the same color to the same terminal

block. See instructions below.

5. Install terminal block into the J-box as shown (location

not important).

6. Tighten nuts on the water-tight strain-reliefs.

7. Assure that gasket is properly installed in the cover.

8. Attach cover using 4 screws (provided).

Installing wires into Terminal Block

1. Open levers 90º to locked position.

2. Insert individual wires into terminal.

3. Close lever.

4. Tug wire to assure solid connection.

Note: Wire strip length is 7/16” (11mm).

406232 J-Box Lever Nut 4Pt (Planter)

141837 Cable - 30Ft J-Box

406074 Cable - 45Ft J-Box

403335 Cable - Power 17Ft 2-Wire

406073 Cable - Power 36Ft 2-Wire

406072 Cable - Power 6Ft 2-Wire

824316 Cable - 15Ft-J-Box

145096 Cable - 70Ft-J-Box

406276 Cable – Power 65Ft 2-Wire