Digi-Star Case IH 1250 - 12/16/24 User Manual

Page 14

Advertising
background image

Trouble Shooting

12

Case IH Planter Scale

D3870-US Rev B

TROUBLE SHOOTING

How to Check the Drill Scale after Installation

For the first test, lift the drill, planter or seeder all the way up, to a level area. Put 200-250 pounds of weight on

the right side, then compare it to the left. Both sides should be within four to six pounds of each other.

If the weight is not within the four to six pound range, inspect the scale system for loose or misalign

mounts.

The second test is to lift the drill, planter or seeder to a level area and zero the scale. Lift the

drill/planter/seeder up and down two to three times, checking to see if the scale zeros out. Each time the scale

is in the up position, it should be within four to six pounds.

If further assistance is necessary, please call Digi-Star, LLC at 920-563-9700.

***The example we are using is 2000 lbs of seed evenly filled in both hoppers. There is 25 lbs of seed left from

the last fill.

Push the “Start” button. The screen will show zero, and the arrow is now pointing to “Net” on the screen. This

is a temporary zero point to start loading the planter with seed. You will now fill 1000 lbs of seed into the left

hopper.

Push the “Stop” button, the readout now reads 1025 lbs of seed inventory.

Push the “Start” button again. The screen will say zero again. Load another 1000 lbs of seed into the right

side.

Now push “Stop” and the screen will read 2025 lbs of seed. The number will decrease as the seed is planted.

Advertising