Scale Kit Mounting Installation – 12, 16 Row

D3870-US Rev B

Case IH Planter Scale

5

Rear Load Cell

12. Remove two bolts that hold the existing catwalk support to catwalk frame. Raise catwalk two

inches.

13. Mount load cell mounting plate to top side of catwalk angle iron frame with 1/2" x 2-1/4” bolt and

1/2" serrated flange nut. Tighten hardware. See Detail C on page 6.

14. Mount rear top bracket to existing catwalk brace with 1/2" x 3-1/2” bolt and 1/2" serrated flange nut.

Leave hardware loose.

15. Mount extra rear center brace to bottom existing catwalk brace with 1/2" x 3.0 bolt and 1/2"

serrated flange nut.

16. Mount Load Cell-1.5SQ DB to rear top bracket with 3/4" x 3.0 bolt and 3/4" top lock nut.

MPORTANT: Make sure the arrow on the end of the load cell is pointed down. Mount short
load cell end (side with single mounting hole) to load cell mounting plate with 3/4" x 2.0 fine
threaded bolt. Apply thread sealant and tighten to 1/16” clearance. See Detail A on page 3.

17. Align all supports and load cell and tighten all hardware.