Scale Kit Mounting Installation – 12, 16 Row

4

Case IH Planter Scale

D3870-US Rev B

Right Side View
































7. Raise hopper leg support 2-3” and mount right hand top support to hopper leg support with two

existing U-bolts and nuts.

Note: Top support should rest against hopper leg support.

8. Mount right hand bottom support to inner planter frame plate with 1/2" x 1.5 bolt and 1/2" serrated

flange nut.

9. Mount load cell to right hand bottom support with 3/4" x 3-1/2” bolt and 3/4" top lock nut.

IMPORTANT: Make sure the arrow on the end of the load cell is pointed down. Mount short
load cell end (side with single mounting hole) to top support with 3/4" x 2.0 fine thread bolt. Apply
thread sealant and tighten to 1/16” clearance. See Detail A on page 3.

10. Align all supports and load cell and tighten all hardware.
11. Repeat for left hand side.