Digi-Star Stockweigh Datamaster Indicator User Manual

Page 23

Advertising
background image

23



ACOPY A:TEST.DAT COM1:@

The Stockweigh Datamaster Indicator will count and show the records downloaded

1. Press ENTER Abort Download? YES.
2. The computer will show: 1 file(s) copied

The transfer is now complete. To check the record, connect the printer and use F5 - Print by weight.


ENTER NEW RECORDS

At the COMMAND!

Press F1, ENTER and follow this example.

1. *2033 lines left
2. *Name: DAY 60
3. *Date: Use the arrow left key and type in a date approx. 60 days hence.
4. *Low: 300
5. *High: 400
6. *Ident? No - unless electronic tags are in use.
7. *Wtgain? Yes
8. *Name: The system will show the last data set on record, if it is not the file to be compared, press the arrow
left and this will scroll the data sets until one is selected.
9. Press ENTER TEST.DAT
10. *Date: 05/09/95 11:30
11. *Ready? Yes
12. Enter the following record:

1. Press the Wt. 500 ASpace bar@.
2. Enter Ident.BBBBB press ASpace bar@.
3. Enter##. Do not enter as this will be used for weight gain stats
4. Enter Coding:BBBB222


SAVE

On the left hand bottom line will show WG=1.1, i.e. a weight gain of 1.1 per day. If a printer is connected the
following record will be printed 500 + BBBBB 1.1BBBB222. The + sign indicates that the weight is over the
target group, the 1.1 is the daily weight gain when compared to the nominated file.

If using in an automatic mode, it will be necessary to press the Check button to bring the result on to the
screen.

For further practice re-enter the records that were downloaded to TEST.DAT but use a weight higher than the
original weight file.