Access type, Transducer block diagram – Flowserve 400MD Logix User Manual

Page 36

Advertising
background image

78

MFG

LEAK_CLASS

NRW

Simple

UNSIGNED8

99

79

MFG

VALVE_FLAGS

NRW

Simple

UNSIGNED8

99

80

MFG

VALVE_TRIMMAT

NRW

Simple

UNSIGNED8

99

81

MFG

VALVE_TRIMCHAR

NRW

Simple

UNSIGNED8

99

82

MFG

VALVE_TRIMTYPE

NRW

Simple

UNSIGNED8

99

83

MFG

VALVE_TRIMNO

NRW

Simple

UNSIGNED8

99

84

MFG

VALVE_SN

NRW

Simple

VISIBLE_STRING

“ “

85

MFG

STEM_DIAM

NRW

Simple

FLOATING_POINT

0

86

MFG

RATED_TRAV

NRW

Simple

FLOATING_POINT

0

87

MFG

INLET_PRESS

NRW

Simple

FLOATING_POINT

0

88

MFG

OUTLET_PRESS

NRW

Simple

FLOATING_POINT

0

89

MFG

ACT_MAN_ID

NRW

Simple

UNSIGNED8

0

90

MFG

ACT_FAIL_ACTION

NRW

Simple

UNSIGNED8

0

91

MFG

ACT_MODEL_NUM

NRW

Simple

VISIBLE_STRING

All “ “

92

MFG

ACT_SN

NRW

Simple

VISIBLE_STRING

All “ “

93

MFG

ACT_TYPE

NRW

Simple

UNSIGNED8

99

94

MFG

ACT_SIZE

NRW

Simple

UNSIGNED8

105

95

MFG

ACT_AREA

NRW

Simple

FLOATING_POINT

23.8

96

MFG

SPRING_TYPE

NRW

Simple

UNSIGNED8

99

97

MFG

PO_DATE

NRW

Simple

VISIBLE_STRING

“ “

98

MFG

INSTALL_DATE

NRW

Simple

VISIBLE_STRING

“ “

99

MFG

MFG_PHONE

NRW

Simple

VISIBLE_STRING

“ “

100

MFG

PUR_ORDER_NUM

NRW

Simple

VISIBLE_STRING

“ “

101

MFG

FINAL_VALUE_RANGE

SRW

Record

SCALE

100.0,0.0,0x53e,1

102

MFG

XD_CAL_LOC

SRW

Simple

VISIBLE_STRING

“ “

103

MFG

XD_CAL_DATE

SRW

Simple

VISIBLE_STRING

“ “

104

MFG

XD_CAL_WHO

SRW

Simple

VISIBLE_STRING

“ “

105

MFG

MAIN_RESERVED_3

RW

Simple

FLOATING_POINT

0

106

MFG

MAIN_RESERVED_4

RW

Simple

FLOATING_POINT

0

107

MFG

CONTROL_CONFIG

NRW

Simple

BIT_STRING

0

108

MFG

MISC_CONFIG

NRW

Simple

BIT_STRING

0

109

MFG

MAIN_BLOCK_TEST

R

Array

UNSIGNED8

0,0,0,0,0,0,0,0

110

MFG

MAIN_RESERVED_5

RW

Simple

FLOATING_POINT

0

111

MFG

EXEC_DELAY

SRW

Simple

UNSIGNED16

0

112

MFG

MAIN_RESERVED_6

RW

Simple

FLOATING_POINT

0

113

MFG

BLINK_CODE

R

Simple

UNSIGNED8

0

Access Type

NOTE: How the Fieldbus board accesses the respective Control board variable.

Std - Standard Parameters. These values are constantly updated from the Control Board, except during the ‘Signature’ capture.

Info - Device Information Parameters. These values are read only at start-up or when any of them are changed. The number -n is used to group
parameters into manageable sizes.

Diag - Advanced Diagnostic

Parameters - These values are active only when the parameter ‘Enable diagnostic Variable Access’ is set in TEST_MODE.

Transducer Block Diagram

Figure 8.2 is a block diagram showing the basic components of the transducer block.

Logix 3400MD Digital Positioner LGENIM3405-02 11/13

36

Advertising