4.1.2 Remounting

STEP 4

a

WARNING: Hazardous Voltage! Turn off all
power sources to actuator before removing
motor assembly. Power sources may include
main power or control power.

Lightly lubricate O-ring (#1-15) that is installed
around the motor spigot/pilot (subassembly #4).

4

1-15

STEP 5

Hold the motor assembly (housing/stator/rotor)
close to the actuator housing and reconnect the
motor power plug to the motor power socket
connector.

5

Motor Power Plug

Motor

Power

Socket

Connector

STEP 6

Coil the spiral-wrapped motor power wiring inside
the motor cavity and around the motor bearing
housing to ensure that it does not come into con-
tact with the rotor shaft.

The motor wiring will wrap around about 180°.