3 remounting – Flowserve MX-85 Actuator User Manual
Page 36
Advertising
Flow Control
Limitorque Actuation Systems
28
MX-85/140 Maintenance and Spare Parts
FCD LMAIM1341-00
STEP 5
Removing worm shaft assembly.
Remove adapter plate, then remove worm assembly.
NOTE: When removing the side-mounted hand-
wheel, the inner bearing (#13-8) should remain in
place in the housing.
Rotate the handwheel assembly clockwise (CW)
to withdraw the complete worm shaft plate
subassembly.
5
STEP 6
If needed, remove the handwheel worm gear
assembly (#12). (See Section 4.8.2 for removal
procedure).
6
Handwheel
Worm Gear Adapter (12-1)
4.3.3 Remounting
STEP 7
Check that bearing (#13-8) is correctly in place in
the actuator housing, it is press fit in the housing.
7
Advertising