1– optional baseplate removal, 2 – optional baseplate remounting – Flowserve QX Limitorque User Manual

Page 43

Advertising
background image

43

Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11

flowserve.com

4.9 Optional Baseplate Assembly, F/FA-05 & -07 QX-1 & 2, F/FA-10 QX-3

thru 5.

4.9.1– Optional Baseplate Removal.

Table 4.20 - Optional Baseplate Removal

ITEM NUMBER

DESCRIPTION

QTY.

16-2

BASEPLATE

1

16-3

SOCKET HEAD CAP SCREWS

4

Figure 4.24 - F/FA-05 / 07, QX-1 & 2 or F/FA-10, QX-3 thru 5 Optional Baseplate

Step 1

QX-1 & 2, MSS FA-05 or -07 baseplate. Using a 5/6” hex key For MSS baseplate, remove the 3/8-16 screws (#4-2)
and remove baseplate (#3).

QX-1 & 2, ISO F-05 or -07 baseplate. Using a M8 hex key For ISO baseplate, remove the M10 screws (#4-2) and
remove baseplate (#3).

QX-3, 4 & 5, MSS FA-10 baseplate. Using a 1/2” hex key For MSS baseplate, remove the 5/8-11 screws (#4-2) and
remove baseplate (#3).

QX-3, 4 & 5, ISO F-10 baseplate. Using a M14 hex key For ISO baseplate, remove the M16 screws (#4-2) and remove
baseplate (#3).

4.9.2 – Optional Baseplate Remounting.

NOTE:

For small baseplate the torque nut must be mounted to drive sleeve before mounting baseplate.

See section 4-11-1.

Place small baseplate on large baseplate aligning pilot. Place screws in baseplate holes and tighten.

Advertising